New Firmware Icom 7300 v1.30 | Icom 7610 v1.10 Cautions

UPDATE 7/30/2018: Icom 7610 Firmware version 1.11 can be found on the Icom Japan website. Click here.

Icom has released new firmware for the Icom 7300 and Icom 7610. For the Icom 7610, if you use software spectrum monitors, ie. N1MM Logger+ Spectrum Monitor, you may want to hold off until Icom fixes the issue that causes the USB CI-V scope waveform to stop working (see below). This is not an issue with the new Icom 7300 firmware.

new firmware icom 7300 7610

New Firmware Icom 7300

The Version 1.30 firmware will provide the following additional functions or changes to your IC-7300.

  • A SET MODE item is added to expand the transmission passband width for the SSB data mode up to "100 to 2900 Hz".
  • A SET MODE item is added to make the USB SEND/USB Keying function active immediately after USB port connection. The Menu structure is changed accordingly.
  • Other performance improvements and bug fixes

Refer to IC-7300 Firmware Update Information Ver.1.30 for more details.

YouTube player

It's always a good idea to follow along in the manual.

New Firmware Icom 7610

(UPDATE 7/30/2018: Icom 7610 Firmware version 1.11 can be found on the Icom Japan website. It fixes version 1.10. Click here.)

Firmware update information— Ver. 1.10

  • RS-BA1 Version 2 is supported.
  • A SET MODE item is added to expand the transmission passband width for the SSB data mode up to "100 to 2900 Hz".
  • A SET MODE item is added to make the USB SEND/USB Keying function active immediately after USB port connection.
  • Output signal for an external display is improved.
  • Other performance improvements and bug fixes

Refer to IC-7610 Firmware Update Information Ver.1.10 for more details.

YouTube player

It's always a good idea to follow along in the manual.

New Firmware Cautions

  1. Save your settings before upgrading firmware in either radio.
  2. Icom 7610 - To update from firmware version 1.05 or older to 1.10, the IC-7610 needs to have firmware version 1.06 installed.
  3. The new Icom 7610 firmware causes the USB CI-V scope waveform to stop working. The spectrum monitors in software such as N1MM Logger+ quit working basically. For that reason some users may want to wait until Icom sends out another update.

Icom introduced an error in the CAT responses that return the spectrum data via the USB port.  In the Icom protocol, each response is supposed to be prefixed with X'FEFE'. They dropped those bytes with the latest firmware upgrade. This in turn caused third party programs following the CAT spec to display spectrum data to fail. - Tom, N1MM

Thank you again for coming by and I appreciate all of the comments. If you have a question please comment below. I will do my best to answer it and your experience will undoubtedly help others as well.

Sources:

UPDATE 7/30/2018: Icom 7610 Firmware version 1.11 can be found on the Icom Japan website. Click here.

Icom Firmware updates

Adam VA7OJ/AB4OJ (From the IC-7300 and IC-7610 Groups.io forum)

Chen, W7AY (From the IC-7610 Groups.io forum)

Tom, N1MM (From the IC-7300 Groups.io forum)

Print Friendly, PDF & Email

K0PIR

I'm an Amateur Radio enthusiast. I love the hobby and experimenting with radios, antennas and software. On my YouTube channel I upload videos on the Icom 7300 and Icom 7610 along with Ham radio software programs. I hope to inspire people to try new things in Amateur Radio.

Subscribe
Notify of
Call
12 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
Guest
Jason Pye KD4LEM
5 years ago

They also have a new driver, but it does not play well eith those of us using Omnirig . The firmware update went well. The new driver threw me for a rabbit hole adventure. I reloaded older driver, now back up and running.

Guest
John
5 years ago

I have the IC-7300 and love its simple to use controls. I’m in the process of gathering all of the resources needed to install FT8. Will this update affect any of the digital settings on the radio – if installed?

Guest
OZ1QX, Eivind
5 years ago

Hi Rich, watched your video clip and wondered that you reformatted the card again.
It’s formatted earlier (it’s an update you’re talking about). Save settings and backup the card to a PC and then copy the extracted firmware ver. 1.30 into the existing 7300 folder on the card and then put the card back on the radio.

Guest
Ken Hendrickson
5 years ago

Could you update your screen shots for the IC-7300 to show the settings changed by the 1.3 firmware.
Thanks,
Ken Hendrickson
w6bzy

Guest
Peter - PA0PJE
5 years ago

Hi Rich,
On the firmware page:
http://www.icom.co.jp/world/support/download/firm/IC-7610/1_11/

IC-7610
Download Type Firmware
Version Version 1.11
Update 2018/07/30
Changes in this version

Fixed an issue where the format of the Scope waveform data (CI-V Command: 27 00) output from the USB is incorrect in firmware version 1.10.

73,
Peter – PA0PJE

Guest
Peter - PA0PJE
5 years ago

Hi Rich,

I wonder if and how we could let Icom open up the 472-479 kHz band for transverter output, as done for 135.7 to 137.8 kHz, as well and I would like to know why the latter is not the case in non-European versions. Many countries in Europe have opened 630 meters for CW and low bandwidth data. As far as I know this is also the case in your hemisphere. I gather this can be implemented in a firmware update.

73,
Peter

Translate »
12
0
Would love your thoughts, please comment.x
()
x